Copyright©HunanSundy Science and Technology Co., Ltd. 2017    湘ICP备10204722号    www.300.cn Changsha Backstage

SDAC6000u Bomb Calorimeter

basic information
Serial number:
描述一
Fully automatic bomb raising & lowering, full test process is less than 10 minutes;
描述二
Optional support stand, customer can choose either benchtop or vertical type
Inventory:
0
没有此类产品
Product description

Highlights:

Optimized design, fully automatic bomb raising & lowering, full test process is less than 10 minutes.

①Unique bucket water circle system, which can determine water volume for each testing automatically. New stainless steel oxygen bomb can be easily assembled and disassembled. High stirring efficiency by propeller, faster heat transfer of oxygen bomb, testing time is greatly reduced. 
②Built-in intelligent water tank with heating and cooling function, water temperature can keep constant, non-stop working available.
③High automation: bomb raising & lowering, determination of bucket water volume and control of water , temperature and test can be finished automatically. 
Good environment adaptability, precise, accurate and reliable rest result.
①Helix tube multipoint isothermal technology, create a controllable and stable internal environment (consists of jacket and jacket lid, temperature difference<0.1℃), stop the interference of external environment (such as air flow, temperature) to bucket, test result is eliable.
②Independent jacket and bucket water system. After the test, bucket water automatically flow back into water tank, no affection between inlet and outlet of bucket water and jacket water. Jacket water temperature is stabilized. 
Accurate and reliable test result
①Larger heat capacity make the testing result is more accurate and reliable.
Reasonable structure, reliable operation, safe and environment friendly
①With self-diagnostic function, malfunction can be detected accurately, easy to maintain.
②Unique crucible support design, convenient to use.

Specification:

Description

SDAC6000u

Analysis Time

Analysis Time: <8min Full Test Process: <10min

Temperature Resolution

0.0001K

Precision(RSD)

≤0.1%

Heat Capacity Stability

≤0.2% within three months

System Structure

Benchtop/Vertical

Conformance with Standard

ASTM D 5865,ISO 1928 GB/T 213-2008

Test per Hour

6

Bomb volume

250ml

Calorimeter Type

Isoperibol

Oxygen Filling

Semi-automatic / automatic

Bomb Washing

Manual

Max.Bomb pressure

20Mp

Bomb Identity

Yes

Gas Requirement

99.5% Oxygen

Water Requirement

Distilled water

Energy Measurement Range

0~50000J

Bucket Filling

Automatic

Constant Volumetric Tank with Temp Control Device

Bucket determine water volume automatically

Independent Bucket and Jacket Water System

Yes

Stirring Method

Propeller

Power Inverter

No

Reproducibility based on analysis of 1g Benzoic Acid

0.10%

Average Temperature Increase

2℃

Temperature Measurement

PT1000

Working Temperatures

≤32℃

Cooling Method

Refrigerating Device

Network

Yes

Power

220V(-10% +10%)50/60Hz

Max.Power

0.6KW

Dimension

Main body: 440*550*460 Water tank: 390*550*440

Weight

50kg

Advance Calculation

Yes

Analysis Report

Yes

Statistics Report

Yes

System Monitor

Yes

 

Spare parts
Video